C
HAPTER
4
68
SmarTrax™ MD Calibration & Operation Manual
ROUTINE OPERATION
ENGAGING SMARTRAX MD
FIGURE 42. SmarTrax MD System Engaged
The steering wheel icon in the lower right corner of the Viper Pro screen indicates whether the SmarTrax MD
system is engaged or disengaged. The steering wheel is green when the system is enabled and gray when it is not.
SmarTrax MD can be engaged in two ways:
• Via the Viper Pro by pressing the steering wheel icon in the lower right corner of the display.
• By tapping the foot/enable switch.
SYSTEM SETTINGS
System Setting
Average
Setting
Suggested
Range
Function
Line Acquisition (LA)
Aggressiveness
10
5 to 13
The LA Aggressiveness value affects how
quickly the machine steers toward a displayed
guidance line when it is traveling further than
24 inches [60 cm] from the desired path.
OnLine (OL) Sensitivity
10
4 to 13
The OL Sensitivity value affects the response of
the machine while steering within 24 inches [60
cm] of the displayed guidance line.
System Setting
Average
Setting
Acceptable
Range
Function
Zero Yaw
0
-2 to 2
Indicates amount error in the internal yaw
sensor while no yaw motion is present.
Message Frequency - GGA
and VTG
10 Hz
10 Hz
Displays the frequency of GGA messages from
the GPS receiver.
Not Enabled
Enabled
Summary of Contents for SmarTrax MD
Page 6: ...Table of Contents iv SmarTrax MD Calibration Operation Manual ...
Page 10: ...CHAPTER 1 4 SmarTrax MD Calibration Operation Manual ...
Page 14: ...CHAPTER 2 8 SmarTrax MD Calibration Operation Manual ...
Page 46: ...CHAPTER 3 40 SmarTrax MD Calibration Operation Manual ...
Page 76: ...CHAPTER 4 70 SmarTrax MD Calibration Operation Manual ...
Page 112: ...CHAPTER 6 106 SmarTrax MD Calibration Operation Manual ...
Page 116: ...CHAPTER 7 110 SmarTrax MD Calibration Operation Manual ...
Page 131: ...P N 016 5030 020 Rev D 125 ROADWAY HOMOLOGATION CERTIFICATION ...
Page 132: ...CHAPTER 8 126 SmarTrax MD Calibration Operation Manual ...