4
P/N 016-5030-020 Rev. D
63
VIPER PRO CALIBRATION AND OPERATION
FIGURE 35. Sensor Status Screen
• The Yaw Sensor Status area of the screen displays the yaw sensor diagnostic information:
◦
Current Wheel Angle
- An approximation of the machine’s wheel angle.
◦
Current Sensor Reading
- The current value of the encoder.
◦
Zero Yaw Button
- Recalibrates the yaw sensor to zero. The machine must be at a full stop before
recalibrating the yaw sensor.
◦
Yaw Zero
- The yaw sensor reading while the machine is stationary. The acceptable operating range for
the Yaw Zero measurement is -2.00 to 2.00. Readings outside this range indicate that a sensor within the
node is operating outside of specifications and that the node must be repaired.
◦
Encoder Cal
- The ratio of the steering wheel movement to the machine’s wheel movement.
SYS DIAG SCREEN