175
SNMP
Simple Network Management Protocol allows CC-SG to push SNMP traps (event notifications)
to an existing SNMP manager on the network. Only a CC-SG Administrator trained in handling
an SNMP infrastructure should configure CC-SG to work with SNMP.
CC-SG also supports SNMP GET/SET operations with third-party enterprise Management
Solutions, such as HP OpenView. To support the operations, you must provide SNMP agent
identifier information such as these MIB-II System Group objects: sysContact, sysName, and
sysLocation. Refer to RFC 1213 for details. These identifiers provide contact, administrative, and
location information regarding the managed node.
MIB Files
Because CC-SG pushes its own set of Raritan traps, you must update all SNMP managers with a
custom MIB file that contains Raritan SNMP trap definitions
⎯
see
Appendix E: SNMP Traps
.
This custom MIB file can be found on the CD included with your CC-SG unit and also under
Firmware Upgrades
on http://www.raritan.com/support.
Configuring SNMP in CC-SG
1.
On the
Setup
menu, click
Configuration Manager.
When the
Configuration Manager
screen appears, click on the
SNMP
tab.
Figure 212 Configuration Settings Device Settings Screen
2.
To identify the SNMP agent running on CC-SG to a third-party enterprise Management
Solutions, provide agent information under
Agent Configuration
. Type a
Port
for the agent,
default is
161.
Type a
Read-Only Community
string, default is
public
, and
Read-Write
Community
string, default is
private
. Multiple community strings are allowed; separate
them with a comma. Type a
System Contact
,
System Name
, and
System Location
to
provide information regarding the managed node.
3.
Click
Update Agent Configuration
to save the SNMP agent identifier information.
4.
Under
Traps Configuration
, check the box marked
Enable SNMP
Traps
to enable sending
SNMP traps from CC-SG to a SNMP host.
5.
Check the box(es) before the trap(s) you want CC-SG to push to your SNMP hosts:
Under
Trap Sources
, there is a list of SNMP traps grouped into two different categories:
Summary of Contents for Command Center CC-SG
Page 2: ...This page intentionally left blank...
Page 16: ......
Page 34: ...18 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 64: ...48 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 122: ...106 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 168: ...152 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 252: ......
Page 254: ...238 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 258: ...242 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 260: ...244 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Page 268: ...252 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE 255 80 5140 00...
Page 269: ...APPENDIX G FAQS 253...