0xF
Denominator Of The
Counts-Per-Physical-
Unit Factor
Denominator of the factor for converting
impulses to physical units.
The factor for the counts per physical unit of
length specifies the unit of length for position
queries and motion commands in closed-loop
operation. The values of every parameter, whose
unit is either the physical unit of length itself or a
unit of measurement based on it, are
automatically adapted to the set factor. The
factor for the counts per physical unit of length
has no impact on the stability of the servo loop
but is used for the input and output scaling of
position values.
Decimal number
0xE
Numerator Of The
Counts-Per-Physical-
Unit Factor
Numerator of the factor for converting impulses
to physical units.
The factor for the counts per physical unit of
length specifies the unit of length for position
queries and motion commands in closed-loop
operation. The values of every parameter, whose
unit is either the physical unit of length itself or a
unit of measurement based on it, are
automatically adapted to the set factor. The
factor for the counts per physical unit of length
has no impact on the stability of the servo loop
but is used for the input and output scaling of
position values.
Decimal number
0xF
Denominator Of The
Counts-Per-Physical-
Unit Factor
Denominator of the factor for converting
impulses to physical units.
The factor for the counts per physical unit of
length specifies the unit of length for position
queries and motion commands in closed-loop
operation. The values of every parameter, whose
unit is either the physical unit of length itself or a
unit of measurement based on it, are
automatically adapted to the set factor. The
factor for the counts per physical unit of length
has no impact on the stability of the servo loop
but is used for the input and output scaling of
position values.
Decimal number
0x14
Has Reference?
Do the mechanics have a reference point switch?
Activates respectively deactivates reference
moves to the installed reference point switch.
0 No reference point switch
1 Reference point switch available
0x5C
Source Of Reference
Signal
Reference signal source for reference moves.
Decimal number, digital input lines bit-mapped
8 E-871.1A1N FUNCTIONS
PZ285EN
‒
1/30/2019
83
M O T I O N | P O S I T I O N I N G