0x15 Maximum Travel In Positive Direction (Phys. Unit)
Used in: Settings for the soft limits (39)
Description:
Soft limit in positive direction, in relation to the zero position.
The positive travel range limit cannot be used for reference moves if
this value is smaller than the position value for the positive travel
range limit (that results from the sum of parameters
).
Data type
FLOAT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
The value can be negative.
0x16 Value At Reference Position (Phys. Unit)
Used in: Settings for the travel range (39)
Description:
Position value at the reference point switch.
The current position is set to this value if the axis has performed a
reference move to the reference point switch.
The parameter value is also used for calculating the position values
set after reference moves to the limit switches; this also applies
when the mechanics do not have a reference point switch.
Data type
FLOAT
Command level
0
Item type
Axis
Source of data
Positioner database
10 PARAMETER REFERENCE
PZ285EN
‒
1/30/2019
181
M O T I O N | P O S I T I O N I N G