0x36 Settling Window (Encoder Counts)
Description:
Settling window around the target position.
Presets the window limits (half of the window width). If the current
position exits the settling window, the target position is no longer
considered as reached.
Can be changed only if the servo mode is switched off.
Data type
INT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0 to 2
31
[encoder counts]
0x3C Stage Name
Description:
Positioner name.
Default value: NOSTAGE
Data type
CHAR
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
String up to 20 characters
0x3F Settling Time (s)
Description:
Delay time for setting the on-target state.
Data type
FLOAT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0.000 to 1.000 [s]
10 PARAMETER REFERENCE
PZ285EN
‒
1/30/2019
186
M O T I O N | P O S I T I O N I N G