8.2.3
Reading Out Recorded Data
Information
Reading the recorded data can take some time, depending on the number of data points.
The data can also be read out while data is being recorded.
Reading data out
1. Read the last recorded data out with the
➔
The data is output in GCS array format.
2. Query the number of points contained in the last recording with the
8.2.4
Commands
D
Page
DRC
Set Data Recorder Configuration
127
DRC?
Get Data Recorder Configuration
128
DRL?
Get Number Of Recorded Points
128
DRR?
Get Recorded Data Values
128
DRT
Set Data Recorder Trigger Source
129
DRT?
Get Data Recorder Trigger Source
130
H
Page
HDR?
Get All Data Recorder Options
134
R
Page
RTR
Set Record Table Rate
156
RTR?
Get Record Table Rate
156
S
Page
STE
Start Step And Response Measurement
162
8.2.5
Parameters
8.3
Digital Inputs and Outputs
The E-871.1A1N's digital inputs and outputs are available at the I/O socket. The number of
available input and output lines to the E-871.1A1N can be queried with the
Overview
Connector of the E-871.1A1N for digital inputs and outputs
8 E-871.1A1N FUNCTIONS
PZ285EN
‒
1/30/2019
75
M O T I O N | P O S I T I O N I N G