SST Set Step Size
Used in: HID Control Configuration (86), Motion in closed-loop operation (32)
Description:
Sets the distance to be travelled for relative motion that is triggered
by an HID.
Long description
Sets the distance (step size) for motion of the specified axis trig-
gered by a manual control unit.
Format:
SST␣{<AxisID>␣<StepSize>}
Arguments:
<AxisID>
Axis ID
<StepSize>
Distance. Specified in the physical unit of the axis
position (format: FLOAT)
Troubleshooting:
Illegal axis identifier
Illegal value
SST? Get Step Size
Used in: HID Control Configuration (86)
Description:
Queries the distance to be travelled for relative motion triggered by
an HID.
Long description
Queries the distance (step size) for motion of the specified axis trig-
gered by a manual control unit.
Format:
SST?␣[{<AxisID>}]
Arguments:
<AxisID>
Axis ID
<StepSize>
Distance. Specified in the physical unit of the axis
position (format: FLOAT)
Response:
{<AxisID>=<StepSize>
␊
}
<AxisID>
Axis ID
StepSize<>
Distance in physical units (format: FLOAT)
Troubleshooting:
Illegal axis identifier
Illegal value
9 COMMAND REFERENCE
PZ285EN
‒
1/30/2019
161
M O T I O N | P O S I T I O N I N G