RS-232C
ZX-GT User’s Manual
120
Set/Acquire IC Lead Pitch/IC Lead Width Standard Values < REF command >
This command is active only when the measurement mode is the IC lead pitch or IC lead
width judgment mode.
Setting standard values
Sets the IC lead pitch/IC lead width standard values.
< Command format >
< Response format >
< Explanation of parameters >
Standard values
Specifies the IC lead pitch/IC lead width standard values.
• IC lead pitch judgment mode (600 to 28000)
• IC lead width judgment mode (300 to 28000)
R E F
CR
Standard values (max. 6 digits)
O K
E R
CR
CR
When processing ends successfully
When processing fails
zx_gt.book Page 120 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...