Setting Thresholds
- T Mode
In this mode, set the measured values for a PASS (OK) judgment. Both HIGH and LOW
threshold values are set. Three judgment results are output; "HIGH", "PASS" and "LOW".
The following describes, as an example, the operation procedure for setting a HIGH threshold.
1
Set the value.
In the special mode (IC lead pitch or IC lead width judgment mode), the following values are
output:
HIGH:Standard value setting
LOW: Tolerance setting
Measurement Cycle p.61
Move from one digit to another.
Change the current value.
Confirm the selection.
Hysteresis can also be set for threshold values. Set hysteresis when judgments are unstable.
Hysteresis p.67
HIGH
ON
OFF
ON
OFF
ON
OFF
LOW
PASS
HIGH threshold
Measured value
LOW threshold
Output
(ON when measured value > HIGH threshold)
(ON when LOW threshold
≤
measured value
≤
HIGH threshold)
(ON when measured value < LOW threshold)
Note
SUB
Measured
value
Threshold
Note
zx_gt.book Page 45 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...