Setting Communication Conditions
ZX-GT User’s Manual
80
Setting Communication Conditions
RS-232C Communications Specifications
Set the communication specifications for the Controller matched to the communications
specifications of external devices. After setting the communications specifications, the
Controller must be turned OFF then back ON again to enable the settings.
1
Select the special setting.
2
Set the baud rate.
3
Set other items by the same procedure.
Setting value
Range
BPS (baud rate)
1200, 2400, 4800, 9600, 19200, 38400
(default value: 38400)
LEN (data length)
7, 8 (default value: 8)
S.BIT
(stop bit)
1, 2 (default value: 1)
PRTY (parity)
NONE (none), ODD (odd), EVEN (even)
(default value: NONE)
HD.FT
(header/footer selection)
ST.ET (STX+ETX), CR, CR.LF (CR+LF)
(default value: CR)
Select [SPCL].
Select [IFU] or [ALL].
Confirm the selection.
Select [BPS].
Change the selection.
Confirm the selection.
SUB
SUB
zx_gt.book Page 80 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...