Setting Measurement Conditions - FUN Mode
43
ZX-GT User’s Manual
2
BA
SIC OPERATIONS
• Adjusting the received light intensity while
viewing the Controller
(1) Received light intensity
The received light intensity is displayed as a
numerical value.
Standard mode (NORM): about 70 or more
High-speed mode (FAST):about 100 or more
Move the emitter to the left and right to adjust
the received light intensity until the display
indicates the above values.
(2) Received light balance
The received light balance of the CCD is displayed.
4
Register the standard received light intensity.
When registration of the standard received light intensity ends normally, [OK] is
displayed on the sub-display after "-----".
When registration of the standard received light intensity fails, an error is displayed.
Standard Received Light Intensity Registration Errors p.141
The received light waveform can be observed in more detail on the exclusive PC
software (SmartMonitor GT (ZX-GSW11)).
Hold down for at least three seconds.
Rece
i
ved
li
ght
ba
l
ance
Rece
i
ved
li
ght
i
ntens
i
ty
SUB
• When one of the sides of the display is missing
Move the emitter in the direction in which the
display is missing to adjust.
• Insufficient received light intensity?
Move the emitter to the left and right to increase
the received light intensity.
• Sync output wired?
Wire the Controller sync output and Sensor
sync input.
• When both sides of the display are missing
• When the center of the display is missing
• Insufficient received light intensity?
Move the emitter to the left and right to increase
the received light intensity.
• Dirty emitter surface or object blocking light path?
Clean the emitter surface or remove object
blocking light path.
Note
zx_gt.book Page 43 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...