I/O Timing Charts
ZX-GT User’s Manual
4
COMMUNICATION
S
WITH EXTERNAL DEVICES
99
Bank switching time
The time after execution of bank switching until output of measurement results is started
is "50 ms + output response time x averaging number". The output response time differs
as follows according to the output destination and settings. Also, the trigger cannot be
input during bank switching. Bank switching is enabled only when the bank switching
setting is set to "external input wire."
Output response time (maximum)
Reset input
Input the reset signal for at least 1 ms. After a reset input, output turns OFF "within the
output response time x averaging number." (analog output maximum value: approx. 5 V/
approx. 23 mA)
Standard mode (NORM)
High-speed mode (FAST)
Judgment output
2.5 ms
1.5 ms
Analog output
2.5 ms
1.5 ms
IFU binary output
Number of connected
Controllers x 0.3 ms + 2.8 ms
Number of connected
Controllers x 0.3 ms + 1.8 ms
zx_gt.book Page 99 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...