RS-232C
ZX-GT User’s Manual
124
How to count edges
Set/Acquire Measured Value/Judgment Result < MEASURE command >
Acquires the measured value. Judgment results are acquired by this command only when
the measurement mode is the IC lead pitch or IC lead width judgment mode.
< Command format >
Note that the edge count method differs from that in the specified edge measurement mode.
Edge count method in the specified edge measurement mode p.57
The boundary between incident light and
interrupted beam sections is counted as an
edge.
Note, however, that when the lower edge
or upper edge of the beam is cut off, the
lower edge or bottom edge also is counted
as an edge.
Note
Beam
Received light
1
2
3
4
Edge No.
Beam
Received light
1
2
3
4
Edge No.
5
6
M E A S U R E
M
M E A S U R E
M
CR
CR
CR
CR
#
#
or
Channel No. (fixed at 2 digits)
Channel No. (fixed at 2 digits)
or
• When there is only one Controller connected
• When multiple Controllers are connected to each other
zx_gt.book Page 124 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...