Mounting and Connecting Devices
ZX-GT User’s Manual
1
BEFORE USE
33
Controller I/O Circuit Diagrams
Make sure that the load connected to "analog output wire (co-axial) - analog GND wire"
satisfies the rating of the set state (voltage or current output) before turning the Controller ON.
Otherwise, the Controller may be damaged.
NPN type Controller (ZX-GTC11)
Important
100
Ω
Brown
Blue
White
Green
Gray
Co-axial (black)
Co-axial (shield)
Load
Load Load Load
24 VDC
HIGH
judgment output
PASS judgment output
LOW judgment output
GND (0 V)
24 VDC
Pink
Purple
Orange
Red
Bank switching input
Timing input
Zero reset input
Reset input
Analog output
Analog GND
Current output: 300
Ω
or less
Voltage output: 10 k
Ω
or more
Voltage output
±4 V
Voltage/Current
switch
Current output
4 to 20 mA
Internal circuit
Output resistance
Yellow
Sync output
Light blue Unused
Black
Unused
zx_gt.book Page 33 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...