Setting Hold Functions
ZX-GT User’s Manual
74
1
Select the hold conditions.
2
Enter the trigger for measurement in the hold
mode.
Connect the Controller's timing input signal wire,
or enter the trigger for starting sampling using the
↑
UP key.
PP-H
(Peak-to-peak hold)
The difference between the minimum and maximum values is held.
This option is selected mainly when detecting vibration. The output
changes at the end of the sampling period, and is held until the end
of the next sampling period.
AVE-H (Average hold)
The average measured value during the sampling period is held.
The output changes at the end of the sampling period, and is held
until the end of the next sampling period.
Select [HOLD].
Change the selection.
Confirm the selection.
Setting value
Description
Sampling period
Current
measured value
Output
(max. value - min.
value)
Min. value
Max. value
Sampling period
Current
measured value
Output
(average of
measured values)
SUB
zx_gt.book Page 74 Wednesday, May 30, 2007 3:29 PM
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...