Adjusting Detection Conditions
ZX-GT User’s Manual
3
FUNCTION SET
TINGS
61
Adjusting Detection Conditions
Measurement Cycle
Normally, set the measurement cycle to the standard mode [NORM].
If the high-speed mode [FAST] is set, the measurement cycle speeds up but the
Controller becomes more susceptible to the influence of ambient light.
1
Select the measurement cycle.
Setting value
Description
NORM (Standard mode)
This mode is for performing measurement with laser emission from
the emitter synchronized with the measurement timing of the
receiver. However, the Controller becomes more resistive to the
influence of ambient light. (default value)
Make sure that the Controller and Sensor sync wires are
connected.
FAST (High-speed
mode)
This mode is for performing measurement at high speed. Note,
however, that the Controller becomes more susceptible to the
influence of ambient light.
Select [SPEED].
Change the selection.
Confirm the selection.
Important
SUB
Chap3.fm 61 ページ 2007年6月6日 水曜日 午前10時45分
Summary of Contents for ZX-GT -
Page 1: ...Smart Sensor Cat No Z263 E1 01 ZX GT Series USER S MANUAL...
Page 12: ...ZX GT User s Manual 10 MEMO...
Page 17: ...CONTENTS ZX GT User s Manual 15 MEMO...
Page 20: ...Operation Step Guide ZX GT User s Manual 18 MEMO...
Page 42: ...Initializing Controller Settings ZX GT User s Manual 40 MEMO...
Page 50: ...Functions and Operations during Operation RUN Mode 48 ZX GT User s Manual MEMO...
Page 90: ...Special Functions ZX GT User s Manual 88 MEMO...
Page 157: ...Compliance with EC Directives ZX GT User s Manual 5 APPENDICES 155 MEMO...
Page 162: ...Quick Reference for Displays ZX GT User s Manual 160 MEMO...