![background image](http://html1.mh-extra.com/html/omron/srm1-programing-02-2001/srm1-programing-02-2001_programming-manual_742414085.webp)
2-2
Section
CPM2A/CPM2C High-speed Counters
64
Programming
ON for 1 cycle at beginning
of operation
Register target value comparison table and begin comparison
High-speed counter
Register target value comparison table and begin comparison
Beginning word of comparison table
Always ON
Always ON
Comparison 2
Comparison 4
Number of comparisons: 5
Target value:
00010000
Comparison 1
Comparison 2
Comparison 3
Comparison 4
Comparison 5
Increment, subroutine 049
Target value:
00003000
Increment, subroutine 040
Target value:
00000000
Decrement, subroutine 010
Target value:
00003000
Decrement, subroutine 041
Target value:
00010000
Decrement, subroutine 048
Always ON
Comparison 5
Always ON
Comparison 1
Always ON
Comparison 3
(71)
(63)
(38)
(93)
(92)
(38)
(93)
(92)
(38)
(93)
(38)
(93)
(92)
(38)
(93)
(01)
(92)
(92)