3-2
Section
Temperature Sensor Units
194
2. Accuracy for a K-type sensor at –100
°
C or less is
±
4
C
±
1 digit max.
3-2-2 CPM2C Temperature Sensor Units
With the CPM2C (including the CPM2C-S), up to four CPM2C-TS001/TS101
Temperature Sensor Units can be connected (up to three Units for the
CPM2C-S). Each Temperature Sensor Unit provides 2 input points meaning that
a total of 8 input points can be used. The inputs can be from thermocouples or
platinum resistance thermometers.
CPM2C CPU Unit
Expansion I/O Unit
CPM2C-TS001/101
Temperature Sensor Units
Temperature inputs
8 points max.
Thermocouples or
platinum resistance
thermometers
Specifications
Item
CPM2C-TS001
CPM2C-TS101
Temperature sensors
Thermocouples
Switchable between K
and J, but same type
must be used for all
inputs.
Platinum resistance
thermometer
Switchable between
Pt100 and JPt100, but
same type must be used
for all inputs.
Number of inputs
2
Allocated input words
2
Max. number of Units
(See note 1.)
4
4
Accuracy
(The larger of
±
0.5% of
converted value or
±
2
C)
±
1 digit max. (See
note.)
(The larger of
±
0.5% of
converted value or
±
1
C)
±
1 digit max.
Conversion time
250 ms for 2 input points
Converted temperature data
16-bit binary data (4-digit hexadecimal)
Isolation
Photocouplers between all temperature input
signals
Note
1. Accuracy for a K-type sensor at –100
°
C or less is
±
4
C
±
1 digit max.
2. The error deviation for temperatures in
°
F is double that for
°
C.