Appendix C
Memory Areas
570
Word(s)
Bit(s)
Function
Read/
write
Page
SR 232
to
SR 235
00 to 15
Macro Function Input Area
Contains the input operands for MCRO(99).
(Can be used as work bits when MCRO(99) is not used.)
Read/
write
157
SR 236
to
SR 239
00 to 15
Macro Function Output Area
Contains the output operands for MCRO(99).
(Can be used as work bits when MCRO(99) is not used.)
SR 240
00 to 15
Input Interrupt 0 Counter Mode SV
SV when input interrupt 0 is used in counter mode (4 digits hexadecimal).
(Can be used as work bits when input interrupt 0 is not used in counter
mode.)
81
SR 241
00 to 15
Input Interrupt 1 Counter Mode SV
SV when input interrupt 1 is used in counter mode (4 digits hexadecimal).
(Can be used as work bits when input interrupt 1 is not used in counter
mode.)
SR 242
00 to 15
Input Interrupt 2 Counter Mode SV
SV when input interrupt 2 is used in counter mode (4 digits hexadecimal).
(Can be used as work bits when input interrupt 2 is not used in counter
mode.)
SR 243
00 to 15
Input Interrupt 3 Counter Mode SV
SV when input interrupt 3 is used in counter mode (4 digits hexadecimal).
(Can be used as work bits when input interrupt 3 is not used in counter
mode.)
SR 244
00 to 15
Input Interrupt 0 Counter Mode PV Minus One
Counter PV–1 when input interrupt 0 is used in counter mode (4 digits hexa-
decimal).
Read-
only
82
SR 245
00 to 15
Input Interrupt 1 Counter Mode PV Minus One
Counter PV–1 when input interrupt 1 is used in counter mode (4 digits hexa-
decimal).
SR 246
00 to 15
Input Interrupt 2 Counter Mode PV Minus One
Counter PV–1 when input interrupt 2 is used in counter mode (4 digits hexa-
decimal).
SR 247
00 to 15
Input Interrupt 3 Counter Mode PV Minus One
Counter PV–1 when input interrupt 3 is used in counter mode (4 digits hexa-
decimal).
SR 248,
SR 249
00 to 15
High-speed Counter PV Area
(Can be used as work bits when the high-speed counter is not used.)
87
SR 250
00 to 15
Analog Setting 0
Used to store the 4-digit BCD set value (0000 to 0200) from analog control 0.
150
SR 251
00 to 15
Analog Setting 1
Used to store the 4-digit BCD set value (0000 to 0200) from analog control 1.