5-3
Section
I/O Allocation for CPM2C PCs
328
Expansion I/O Units with 32 I/O Points
CPM2C-32EDTC
CPM2C-32EDT1C
CPM2C-32EDTM
CPM2C-32EDT1M
Inputs
m+1
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
16 inputs
Word (m+1), bit 00
to
Word (m+1), bit 15
16 outputs
Word (n+1), bit 00
to
Word (n+1), bit 15
Outputs
n+1
Bits
5-3-3 Expansion Units
Unit
Model number
I/O
Allocated words
Max. No. of Units
CPM2C
CPM2C-S
Analog I/O Unit
CPM2C-MAD11
Input
2 inputs: m+1, m+2
4
3
g
Output
1 output: n+1
Temperature Sensor Unit
CPM2C-TS001
CPM2C TS101
Input
2 inputs: m+1, m+2
4
3
p
CPM2C-TS101
Output
---
CompoBus/S I/O Link Unit
CPM2C-SRT21
Input
1 input: m+1
5
3
p
Output
1 output: n+1
Note
1. m:
“m” denotes the last input word allocated to the CPU Unit, or to the pre-
vious Expansion Unit or Expansion I/O Unit if one is already connected.
n:
“n” denotes the last output word allocated to the CPU Unit, or to the pre-
vious Expansion Unit or Expansion I/O Unit if one is already connected.
2. Because the CPM2C-MAD11 Analog I/O Unit and the CPM2C-TS001/101
Temperature Sensor Units require 2 I/O words each, only 4 of these Units
can be connected to the PC. (The CPU Unit itself requires one input word
and one output word.) A different Unit, such as an Expansion I/O Unit or the
CPM2C-SRT21 CompoBus/S I/O Link Unit, can, however, be connected in
addition to 4 Analog I/O Units or Temperature Sensor Units.
Analog I/O Unit
CPM2C-MAD11
2 analog inputs
Input 0: word (m+1)
Input 1: word (m+2)
1 analog output
Output 0: word (n+1)