4-5
Section
Host Link Commands
286
Response Format
An end code of 00 indicates normal completion.
@
W
L
x 10
1
x 10
0
x 16
1
x 16
0
↵
FCS
Node no.
End code
Header
code
Terminator
Parameters
Write Data (Command)
Specify in order the contents of the number of words to be written to the LR area
in hexadecimal, starting with the specified beginning word.
Note
If data is specified for writing which exceeds the allowable range, an error will be
generated and the writing operation will not be executed. If, for example, 12 is
specified as the beginning word for writing and five words of data are specified,
then 16 will become the last word for writing data, and the command will not be
executed because LR 16 is beyond area boundary.
4-5-10 HR AREA WRITE – WH
Writes data to the HR area, starting from the specified word. Writing is done word
by word.
Command Format
@
W
H
FCS
x 10
1
x 10
0
x 10
3
x 10
2
↵
x 10
1
x 10
0
x 16
3
x 16
2
x 16
1
x 16
0
Node no.
Header
code
Beginning word*
Write data
(for no. of words to write)
Write data (1 word)
Terminator
Note
Beginning word:0000 to 0019
Response Format
An end code of 00 indicates normal completion.
@
W
H
x 10
1
x 10
0
x 16
1
x 16
0
↵
FCS
Node no.
End code
Header
code
Terminator
Parameters
Write Data (Command)
Specify in order the contents of the number of words to be written to the HR area
in hexadecimal, starting with the specified beginning word.
Note
If data is specified for writing which exceeds the allowable range, an error will be
generated and the writing operation will not be executed. If, for example, 18 is
specified as the beginning word for writing, and three words of data are speci-
fied, then 20 will become the last word for writing data, and the command will not
be executed because HR 20 is beyond area boundary.
4-5-11 PV WRITE – WC
Writes the PVs (present values) of timers/counters starting from the specified
timer/counter.