![background image](http://html1.mh-extra.com/html/omron/srm1-programing-02-2001/srm1-programing-02-2001_programming-manual_742414271.webp)
4-3
Section
CPM2A/CPM2C Communications Functions
251
In the following program example TXD(48) is used to transmit data from an
RS-232C port to a host computer. If AR 0805 (the RS-232C Transmit Ready
Flag) is ON when IR 00100 turns ON, the ten bytes of data (DM 0100 to
DM 0104) will be transmitted to the host computer, leftmost bytes first.
Leading address of data to be transmitted
RS-232C port specification
10 bytes
(48)
4-3-2 No-protocol Communications
Overview
When no-protocol communications are used, data can be exchanged with serial
devices such as bar code readers and serial printers using TXD(48) and
RXD(47). No-protocol communications can be used with either an RS-232C
port or peripheral port.
CPM2A Connections
RS-232C devices
Bar code reader
Serial printer
Other
CPM2A CPU Unit
RS-232C port
CPM2A CPU Unit
CPM2A CPU Unit
Peripheral port
Peripheral port
CPM1-CIF01 RS-232C Adapter
(
CTS control cannot be used.
)
CQM1-CIF01/02 RS-232C Adapter
(
CTS control cannot be used.
)
RS-232C devices
Bar code reader
Serial printer
Other
RS-232C devices
Bar code reader
Serial printer