4-5
Section
Host Link Commands
298
Parameters
Name, Word address, Bit (Command)
In “Name,” specify the area (i.e., IR, SR, LR, HR, AR, or TC) that is to be forced
reset. Specify the name in four characters. In “Word address,” specify the ad-
dress of the word, and in “Bit” the number of the bit that is to be forced reset.
Name
Classification
Word address setting range
Bit
OP1
OP2
OP3
OP4
CPM2A/
CPM2C PCs
CPM1/CPM1A
/SRM1(-V2)
PCs
C
I
O
(Space) IR or SR
0000 to 0049
0200 to 0252
0000 to 0019
0200 to 0252
00 to 15
(decimal)
L
R
(Space) (Space) LR
0000 to 0015
0000 to 0015
(dec
a )
H
R
(Space) (Space) HR
0000 to 0019
0000 to 0019
A
R
(Space) (Space) AR
0000 to 0023
0000 to 0015
T
I
M
(Space) Completion Flag (timer)
0000 to 0255
0000 to 0127
Always 00
T
I
M
H
Completion Flag (high-speed timer)
y
T
I
M
L
Completion Flag (long timer)
T
M
H
H
Completion Flag (very high-speed timer)
C
N
T
(Space) Completion Flag (counter)
C
N
T
R
Completion Flag (reversible counter)
Note
The area specified under “Name” must be in four characters. Add spaces after
the data area name if it is shorter than four characters.
4-5-24 MULTIPLE FORCED SET/RESET – FK
Force sets, force resets, or cancels the status of the bits in one word in the IR,
SR, LR, HR, AR, or TC area.
Command Format
@
F
K
x 10
0
x 10
1
x 10
3
x 10
2
x 10
1
x 10
0
OP1 OP2 OP3
OP4
↵
15
14
13
12
11
10
1
0
Node no.
Header
code
Name
Word
address
Forced set/reset/cancel data
Bit
x 16
0
x 16
0
x 16
0
x 16
0
x 16
0
x 16
0
x 16
0
x 16
0
Terminator
FCS
Response Format
An end code of 00 indicates normal completion.
@
F
K
x 10
0
x 10
1
x 16
1
x 16
0
↵
Node no.
Header
code
Terminator
FCS
End code