2-7
Section
Synchronized Pulse Control (CPM2A/CPM2C Only)
143
Relationship Between Status and Operation
Frequency
Input pulses
Time
Frequency
Output pulses
Time
SYNC(––) execution
INI(61) execution
Output 0 in progress
Output 1 in progress
Application Example
Explanation
In this example, when the execution condition (00005) turns ON, synchronized
pulse control is started and pulses are output from output 01000 (pulse output 0)
according to the pulses input by the high-speed counter. At this time, the fre-
quency scaling factor can be changed by means of analog control 0. When the
execution condition (00005) turns OFF, synchronized pulse control is stopped.
Wiring
Wire the CPM2A as shown in the following illustration.
Rotary encoder
Motor driver
Brown
Blue
Black
White
Orange
Wire the CPM2C as shown in the following illustration. In this case, a CPU Unit
with sinking transistor outputs is used.