75
Communicating with the PLC Using C200H Direct Communications
Section 2-7
I/O Connecting Cable
Use the following models of I/O Connecting Cable.
Note
The C200H interface connector of NT20M-CNP
@@@
has been
downsized.
!Caution
Keep the total length of I/O cables used within 12 m (6 m for C
@@
H).
!Caution
The cable's tensile load is 30 N. Do not subject it to loads greater than this.
Otherwise a discontinuity may occur, causing operation to fail.
Reference:
If a C200H-CN
@@@
or C20H-CN
@@@
is used as the I/O Connecting Cable,
the connector will project beyond the bottom face of the NT20.
If the I/O cable is passed through a hole or other opening, the diameter of the
hole or opening must be at least 53 mm
φ
. Removing the top cover reduces
this requirement to 33 mm
φ
or larger. During installation, this cover must be
replaced before securing the PT.
Connection to C200H/
C200HS and C200HX/HG/
HE
Connect the CPU Rack or Expansion I/O Rack with an I/O cable. The follow-
ing restrictions apply when making this connection.
• A maximum of one CPU Rack and one Expansion I/O Rack can be con-
nected. Connection to two Expansion I/O Racks is not possible.
• Connection to a Remote Rack is not possible.
Model
Cable Length (L)
For connecting C200H/HS/HE/HG/HX
C200H-CN311
30 cm
NT20M-CNP711
C200H-CN711
70 cm
NT20M-CNP221
C200H-CN221
2 m
NT20M-CNP521
C200H-CN521
5 m
NT20M-CNP131
C200H-CN131
10 m
For connecting C
@@
H
C20H-CN312
30 cm
NT20M-CNP712
C20H-CN712
70 cm
NT20M-CNP222
C20H-CN222
2 m
Summary of Contents for NT20
Page 1: ...Programmable Terminal Cat No V091 E1 01 NT20 USER S MANUAL ...
Page 2: ...NT series Programmable Terminal User s Manual Produced March 2007 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 9: ...x TABLE OF CONTENTS ...
Page 15: ...xvi ...
Page 21: ...xxii EC Directives 6 ...
Page 37: ...16 Before Operating Section 1 6 ...
Page 153: ...132 Transferring the Resource Data Section 3 11 ...
Page 185: ...164 Numeral Setting Section 4 8 ...
Page 267: ...246 Key to Programs Section 6 8 ...
Page 281: ...260 Specifications Appendix A ...
Page 285: ...264 Transporting and Storing PTs Appendix C ...
Page 303: ...282 Function Restrictions Depending on the Support Tool Appendix I ...
Page 307: ...286 Index ...
Page 309: ...288 Revision History ...