90
Initializing Memory
Section 3-4
3-4-2
Initialization by Using the DIP Switch (Forced Initialization)
Note
Be sure to turn the power OFF before setting the NT20 DIP switch.
Set the DIP switch as follows to initialize the screen data memory.
1,2,3...
1.
Set DIP SW2-1 on the NT20 to ON and turn the power ON or reset the
NT20.
2.
Turn the NT20 power to OFF.
3.
Set NT20 DIP SW2-1 to OFF and turn the power ON.
Note
(1) Selecting “No” will cancel the memory initialization. In either case, when
changing the system settings or registering screen data, display the sys-
tem menu after setting DIP switch SW2-1 to the OFF position while the
NT20 power is OFF, then switching the power back ON.
(2) The NT20 DIP SW2-1 is used to set “Screen data forced initialize Yes/
No”. Setting this to Yes selects “effective”, and No “ineffective”.
Initialize Screen Memory?
Yes
No
Select “Yes”.
The screen data memo-
ry is initialized. During
the initialization, the “Ini-
tializing” message will
be displayed.
Turn OFF the DIP Switch 2-1
and push the Reset Switch,
then return to RUN mode.
Initialized the
Screen Data Memory.
Summary of Contents for NT20
Page 1: ...Programmable Terminal Cat No V091 E1 01 NT20 USER S MANUAL ...
Page 2: ...NT series Programmable Terminal User s Manual Produced March 2007 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 9: ...x TABLE OF CONTENTS ...
Page 15: ...xvi ...
Page 21: ...xxii EC Directives 6 ...
Page 37: ...16 Before Operating Section 1 6 ...
Page 153: ...132 Transferring the Resource Data Section 3 11 ...
Page 185: ...164 Numeral Setting Section 4 8 ...
Page 267: ...246 Key to Programs Section 6 8 ...
Page 281: ...260 Specifications Appendix A ...
Page 285: ...264 Transporting and Storing PTs Appendix C ...
Page 303: ...282 Function Restrictions Depending on the Support Tool Appendix I ...
Page 307: ...286 Index ...
Page 309: ...288 Revision History ...