![background image](http://html1.mh-extra.com/html/omron/ej1-ethercat/ej1-ethercat_user-manual_742375278.webp)
253
Parameter List
Appendix
Variable
type
CompoWay/F
Modbus
Parameter name
Setting (monitor) range
De-
fault
Unit
Attrib-
utes
Target Unit
Category
Add-
ress
Address
TC4/
TC2
HFU
F2 (B2)
Enabled
after
resetting.
0000
A400
Event Input 1 Assignment
H' 00000000: Disabled (0)
H' 00000001: All channels Bank (bit0) (1)
H' 00000002: All channels Bank (bit1) (2)
H' 00000003: All channels Stop (0)/Run (1) (3)
H' 00000004: All channels Run (0)/Stop (1) (4)
H' 00000005: All channels Auto (0)/Manual (1) (5)
H' 00000006: All channels SP mode (Local (0)/Remote
(1)) (6)
0
---
Common
TC2
---
Not used.
H' 00000020: CH1 Bank (bit0) (32)
H' 00000021: CH1 Bank (bit1) (33)
H' 00000022: CH1 Stop (0)/Run (1) (34)
H' 00000023: CH1 Run (0)/Stop (1) (35)
H' 00000024: CH1 Auto (0)/Manual (1) (36)
H' 00000025: CH1 SP mode (Local (0)/Remote (1)) (37)
Not used.
H' 00000040: The rest are the same as channel 1. (64)
···
0001
A401
Event Input 2 Assignment
The rest are the same as Event Input 1 Assignment.
Not used.
0010
A410
Auxiliary Output 1 Assignment
H' 00000000: Disabled (0)
H' 00000001: Temperature Controller error (1)
20
---
Common
---
●
Not used.
H' 00000010: Event input 1 (16)
H' 00000011: Event input 2 (17)
H' 00000012: Event input 3 (18)
H' 00000013: Event input 4 (19)
H' 00000014: Bus input 1 (20)
H' 00000015: Bus input 2 (21)
H' 00000016: Bus input 3 (22)
0011
A411
Auxiliary Output 2 Assignment
The rest are the same as Auxiliary Output 1 Assignment. 21
0012
A412
Auxiliary Output 3 Assignment
22
0013
A413
Auxiliary Output 4 Assignment
0
Not used.
0020
A420
Bus Input 1 Assignment
H' 00000000: Disabled (0)
H' 00000001: All channels Bank (bit0) (1)
H' 00000002: All channels Bank (bit1) (2)
H' 00000003: All channels Stop (0)/Run (1) (3)
H' 00000004: All channels Run (0)/Stop (1) (4)
H' 00000005: All channels Auto (0)/Manual (1) (5)
H' 00000006: All channels SP mode (Local (0)/Remote
(1)) (6)
0
---
Common
●
---
Not used.
H' 00000020: CH1 Bank (bit0) (32)
H' 00000021: CH1 Bank (bit1) (33)
H' 00000022: CH1 Stop (0)/Run (1) (34)
H' 00000023: CH1 Run (0)/Stop (1) (35)
H' 00000024: CH1 Auto (0)/Manual (1) (36)
H' 00000025: CH1 SP mode (Local (0)/Remote (1)) (37)
Not used.
H' 00000040: Channel 2: The same as channel 1. (64)
···
H' 00000060: Channel 3: The same as channel 1. (96)
TC4
---
···
H' 00000080: Channel 4: The same as channel 1. (128)
···
0021
A421
Bus Input 2 Assignment
The rest are the same as Bus Input 1 Assignment.
0022
A422
Bus Input 3 Assignment
Summary of Contents for EJ1 EtherCAT
Page 2: ...EJ1 Modular Temperature Controllers User s Manual Revised July 2008 ...
Page 3: ...iv ...
Page 19: ...xx ...
Page 213: ...188 Detailed Description of Services Section 6 4 ...
Page 227: ...202 Detailed Description of Services Section 7 5 ...
Page 303: ...278 Index ...
Page 305: ......