236
Parameter List
Appendix
Note
(1) The decimal point position is determined by the sensor selection.
(2) The decimal point position is determined by the sensor selection. In this case, however, the 0 (****)
decimal point position setting will be treated as a setting of 1 (***.*).
Variable
type
CompoWay/F
Modbus
Parameter name
Setting (monitor) range
De-
fault
Unit
Attrib-
utes
Target Unit
Category
Add-
ress
Address
TC4/
TC2
HFU
C9 (89)
Monitor
0100
E000
G3PW1 - Output Monitor
H' 00000000 to H' 000003E8 (0.0 to 100.0)
0.0
%
NUM
●
---
Not used.
0108
E008
G3PW1 - Status
---
---
---
NUM
●
---
Not used.
0110
E00A
G3PW1 - Current Monitor
H' 00000000 to H' 000002EE (0.0 to 75.0)
0.0
A
NUM
●
---
Not used.
0200
E100
G3PW2 - Output Monitor
The rest are the same as the G3PW1.
···
···
···
0300
E200
G3PW3 - Output Monitor
···
···
···
0400
E300
G3PW4 - Output Monitor
··
·
··
·
··
·
0500
E400
G3PW5 - Output Monitor
···
···
···
0600
E500
G3PW6 - Output Monitor
···
···
···
0700
E600
G3PW7 - Output Monitor
···
···
···
0800
E700
G3PW8 - Output Monitor
···
···
···
Variable
type
CompoWay/F
Modbus
Parameter name
Setting (monitor) range
De-
fault
Unit
Attrib-
utes
Target Unit
Category
Add-
ress
Address
TC4/
TC2
HFU
D0 (90)
Can be
changed
during
operation.
0100
0240
Bank 0 Set Point - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0101
0241
Bank 0 Proportional Band - CH1
H' 00000001 to H' 0000270F (0.1 to 999.9) (See note 2.)
8.0
EU
BANK
●
---
0102
0242
Bank 0 Integral Time - CH1
H' 00000000 to H' 00000F9F (0 to 3999)
233
s
BANK
●
---
0103
0243
Bank 0 Derivative Time - CH1
H' 00000000 to H' 0000270F (0.0 to 999.9)
40.0
s
BANK
●
---
0104
0244
Bank 0 SP Ramp Rise Value -
CH1
H' 00000000 to H' 0000270F (0 to 9999)
(Function stops when set to 0.) (See note 1.)
0
EU/s or
EU/min
BANK
●
---
0105
0245
Bank 0 SP Ramp Fall Value -
CH1
H' 00000000 to H' 0000270F (0 to 9999)
(Function stops when set to 0.) (See note 1.)
0
EU/s or
EU/min
BANK
●
---
Not used.
0107
0247
Bank 0 Manual Reset Value -
CH1
H' 00000000 to H' 000003E8 (0.0 to 100.0)
50.0
%
BANK
●
---
0108
0248
Bank 0 Cooling Coefficient - CH1 H' 00000001 to H' 0000270F (0.01 to 99.99)
1.00
---
BANK
●
---
0109
0249
Bank 0 Dead Band - CH1
H' FFFFF831 to H' 0000270F (
−
199.9 to 999.9) (See note 2.) 0.0
EU
BANK
●
---
Not used.
010D 024D
Bank 0 Alarm Value 1 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
010E
024E
Bank 0 Alarm Upper Limit Value
1 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
010F
024F
Bank 0 Alarm Lower Limit Value
1 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0110
0250
Bank 0 Alarm Value 2 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0111
0251
Bank 0 Alarm Upper Limit Value
2 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0112
0252
Bank 0 Alarm Lower Limit Value
2 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0113
0253
Bank 0 Alarm Value 3 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0114
0254
Bank 0 Alarm Upper Limit Value
3 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0115
0255
Bank 0 Alarm Lower Limit Value
3 - CH1
H' FFFFF831 to H' 0000270F (
−
1999 to 9999) (See note 1.)
0
EU
BANK
●
---
0116
0256
Bank 0 Proportional
Band (Cooling) - CH1
H' 00000001 to H' 0000270F (0.1 to 999.9) (See note 2.)
8.0
EU
BANK
●
---
0117
0257
Bank 0 Integral Time
(Cooling) - CH1
H' 00000000 to H' 00000F9F (0 to 3999)
233
s
BANK
●
---
0118
0258
Bank 0 Derivative Time
(Cooling) - CH1
H' 00000000 to H' 0000270F (0.0 to 999.9)
40.0
s
BANK
●
---
Not used.
0200
0440
Bank 0 Set Point - CH2
The rest are the same as channel 1.
··
·
··
·
··
·
0300
0640
Bank 0 Set Point - CH3
TC4
---
···
···
···
0400
0840
Bank 0 Set Point - CH4
TC4
---
···
···
···
V1.2
V1.2
V1.2
Summary of Contents for EJ1 EtherCAT
Page 2: ...EJ1 Modular Temperature Controllers User s Manual Revised July 2008 ...
Page 3: ...iv ...
Page 19: ...xx ...
Page 213: ...188 Detailed Description of Services Section 6 4 ...
Page 227: ...202 Detailed Description of Services Section 7 5 ...
Page 303: ...278 Index ...
Page 305: ......