![background image](http://html1.mh-extra.com/html/omron/ej1-ethercat/ej1-ethercat_user-manual_742375082.webp)
57
Setting Output Specifications
Section 4-2
4-2
Setting Output Specifications
4-2-1
Control Output Assignments
The parameters shown in the following diagram can be assigned to each out-
put by setting the control output assignments.
The same parameter can be assigned to different outputs.
Note
(1) Temperature Controller Error
The Temperature Controller Error output will turn ON when an bit be-
tween bit 0 and bit 13 in the Device A Status is ON. It can be used to out-
put EJ1 error status. Refer to
Status Lists
on page 255 for details on
Device A Status.
(2) If any parameters other than those marked with *1 and *2 are assigned
to outputs for Controllers with linear outputs, 100% will be output for ON
and 0% will be outputs for OFF. This will also apply to parameters marked
with *2 if the control method is set to ON/OFF control.
Note
These parameters can be set only when operation is stopped.
Refer to
Parameter List
on page 233 for details on the settings.
Channel 4
Channel 4
Channel 2
•
OUT2, OUT3, and OUT4 can be set in the same way.
•
Channels 3 and 4 are supported only by the TC4.
Input Error OR
RSP Input Error OR
Alarm 1 to 3 OR
Alarm 1 to 3 AND
HB (Heater Burnout) Alarm OR
HS (Heater Short) Alarm OR
OC (Heater Overcurrent) Alarm OR
All Alarm AND
All Alarm OR
All channels
Disabled
Temperature Controller Error
Settable
parameters
OUT1
OUT2
OUT3
OUT4
HS (SSR Failure) Alarm
Heater Burnout Alarm
RSP Input Error
Input Error
Alarm 1 to 3
OC (Heater Overcurrent) Alarm
Channel 4
All Alarm AND
All Alarm OR
Process Value
Internal SP
Local SP
Remote SP
Control Output (Heating)
Transfer Output (Heating)
Control Output (Cooling)
Transfer Output (Cooling)
HS (SSR Failure) Alarm
Heater Burnout Alarm
RSP Input Error
Input Error
Alarm 1 to 3
OC (Heater Overcurrent) Alarm
Channel 3
All Alarm AND
All Alarm OR
Process Value
Internal SP
Local SP
Remote SP
Control Output (Heating)
Control Output (Cooling)
Transfer Output (Cooling)
HS (SSR Failure) Alarm
Heater Burnout Alarm
RSP Input Error
Input Error
Alarm 1 to 3
OC (Heater Overcurrent) Alarm
Channel 2
All Alarm AND
All Alarm OR
Process Value
Internal SP
Local SP
Remote SP
Control Output (Heating)
Transfer
Output (Cooling)
Transfer
Output (Heating)
Transfer Output (Heating)
Control Output (Cooling)
*1
*2
HS (Heater Short) Alarm
HB (Heater Burnout) Alarm
RSP Input Error
Input Error
Alarm 1 to 3
OC (Heater Overcurrent) Alarm
Channel 1
All Alarm AND
All Alarm OR
Process Value
Internal SP
Local SP
Remote SP
Control Output (Heating)
Control Output (Cooling)
Transfer Output (Cooling)
Transfer Output (Heating)
Variable type
Parameter name
Setting range
Default
TC4 TC2
E1/A1
Control Output 1 Assignment (I/O) 0 to 144
47
Control Output 2 Assignment (I/O) 0 to 144
79
Control Output 3 Assignment (I/O) 0 to 144
111
32
Control Output 4 Assignment (I/O) 0 to 144
143
64
Conditions for use
No special conditions
Summary of Contents for EJ1 EtherCAT
Page 2: ...EJ1 Modular Temperature Controllers User s Manual Revised July 2008 ...
Page 3: ...iv ...
Page 19: ...xx ...
Page 213: ...188 Detailed Description of Services Section 6 4 ...
Page 227: ...202 Detailed Description of Services Section 7 5 ...
Page 303: ...278 Index ...
Page 305: ......