49
Axis
Description
Name
R/W
Address
Task 1
status
6020
R
Executing program no.
If a program is being executed, the number of the
program will be output and if no program is being
executed, the number of the last program executed
will be output within a range of 0 to 999.
0
0
0
0
0 x10
2
x10
1
x10
0
L+1
L
6021
R
Executing block no.
If a program is being executed, the block number of
the program will be output and if no program is being
executed, the block number of the last program
executed will be output within a range of 0 to 999.
0
0
0
0
0 x10
2
x10
1
x10
0
L+1
L
6022
R
Teaching execution
address
Outputs the address where the position data is stored
at the time of teaching within a range of 0 to 1,999.
The address will be refreshed whenever teaching is
executed.
0
0
0
0
x10
2
x10
1
x10
0
L+1
L
x10
3
Task 2
6024
R
Executing program no.
Refer to the corresponding task 1 data.
status
6025
R
Executing block no.
p
g
6026
R
Teaching execution
address
Current
position
6050
R
Reference
coordinate system
current position
X
X-axis reference coordinate system current position
Y-axis reference coordinate system current position
x10
7
x10
6
x10
5
x10
4
x10
3
x10
2
x10
1
x10
0
L+1
L
3 2 1 0 bit
x10
7
Sign bit
0: Positive
1: Negative
x10
7
x10
6
x10
5
x10
4
x10
3
x10
2
x10
1
x10
0
L+1
L
6051
R
Y
Outputs the reference coordinate system current
position within a range of –39,999,999 to 39,999,999.
The minimum setting unit is set to 2 (for 0.01), the
display unit is set to 0 (for mm), and the reference
coordinate system current position is 3.99 mm (i.e.,
399 x 0.01) if the data is 399.
x10
7
x10
6
x10
5
x10
4
x10
3
x10
2
x10
1
x10
0
3 2 1 0 bit
x10
7
Sign bit
0: Positive
1: Negative
6054
R
Workpiece
coordinate system
current position
X
Outputs the workpiece coordinate system current
position.
There is no difference in data configuration, range, or
6055
R
current position
Y
There is no difference in data configuration, range, or
unit between the work coordinate system current
position and reference coordinate system current
position.
Details of Data Transmission and Reception Units
Section 4-4
Summary of Contents for C200H-MC221 -
Page 1: ...Cat No W315 E1 03 Motion Control Unit C200H MC221 OPERATION MANUAL ...
Page 2: ......
Page 3: ...C200H MC221 Motion Control Unit Operation Manual Details Revised June 2010 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 10: ......
Page 12: ......
Page 16: ...xvi ...
Page 42: ......
Page 48: ......
Page 196: ......
Page 212: ......
Page 242: ......
Page 258: ......
Page 304: ......