155
6-5-25 Word n+5 Bit 08: Enable MPG Bit (X-axis)
This bit is used to start MPG operation; it is valid only when the mode is set to
manual mode. As long as this bit is ON, the command will reference the MPG
Ratio Specifiers (n+5 bits 14 and 15), read the input pulses from the MPG, multi-
ply them by the MPG ratio, and perform MPG operation.
MPG operation will be stopped when this bit goes OFF. This bit is ignored if the
Busy Flag is ON. This function is available to the X axis only.
Signal
The Enable MPG Bit settings have the following functions.
Signal
Function
↑
(OFF-to-ON)
Starts MPG operation.
↓
(ON-to-OFF)
Stops MPG operation.
Timing Chart
Enable MPG Bit
(n+5 bit 08)
Busy Flag
(n+16 bit 01)
MPG pulse input
20 ms min.
20 ms min.
Axis Operating Flag
(n+16 bit 04)
Positioning Completed
Flag (n+16 bit 05)
MPG Operation Flag
(n+19 bit 15)
Program Example
n+5
14
n+5
15
OUT
(Sets MPG
Ratio
Specifier 1.)
OUT
(Sets MPG
Ratio
Specifier 2.)
OUT
(Starts MPG
operation.)
Ratio specifier 1
condition
Ratio specifier 2
condition
Enable
MPG
condition
n+5
08
Interface Bit Specifics
Section 6-5
Summary of Contents for C200H-MC221 -
Page 1: ...Cat No W315 E1 03 Motion Control Unit C200H MC221 OPERATION MANUAL ...
Page 2: ......
Page 3: ...C200H MC221 Motion Control Unit Operation Manual Details Revised June 2010 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 10: ......
Page 12: ......
Page 16: ...xvi ...
Page 42: ......
Page 48: ......
Page 196: ......
Page 212: ......
Page 242: ......
Page 258: ......
Page 304: ......