131
Word
Page
Description
Bit
n+19
Y-axis
Status
00
Reference Origin
1
Within the in-position range of the
reference origin.
170
S a s
Flags
0
Outside the in-position range of the
reference origin.
01
Busy Flag
1
A manual command is being executed.
170
y
g
0
Other than the above.
02
Servo Lock ON
1
Servo lock status
171
0
Servo free status
03
No Origin Flag
1
No origin (The reference origin isn’t fixed.) 171
g
g
0
The reference origin is fixed.
04
Axis Operating
1
There is an axis movement command.
172
p
g
0
There isn’t an axis movement command.
05
Positioning Completed
1
Within the in-position range
173
g
p
0
Outside the in-position range
06
Error Counter Alarm
1
The number of accumulated pulses in the
error counter exceeds the error counter
warning value.
173
0
Other than the above.
07
Alarm Input
1
The driver alarm input is ON.
174
p
0
The driver alarm input is OFF.
08
Zone 1 Flag
1
Within zone 1.
174
g
0
Outside of zone 1.
09
Zone 2 Flag
1
Within zone 2.
g
0
Outside of zone 2.
10
Zone 3 Flag
1
Within zone 3.
g
0
Outside of zone 3.
11
Zone 4 Flag
1
Within zone 4.
g
0
Outside of zone 4.
12
Zone 5 Flag
1
Within zone 5.
g
0
Outside of zone 5.
13
Zone 6 Flag
1
Within zone 6.
g
0
Outside of zone 6.
14
Zone 7 Flag
1
Within zone 7.
g
0
Outside of zone 7.
15
Zone 8
Fl /MPG
Zone 8
Fl
1
Within zone 8.
Flag/MPG
valid
Flag
0
Outside of zone 8.
valid
MPG in
i
1
MPG operation is being performed.
174
operation
0
Other than the above.
Interface Bits
Section 6-4
Summary of Contents for C200H-MC221 -
Page 1: ...Cat No W315 E1 03 Motion Control Unit C200H MC221 OPERATION MANUAL ...
Page 2: ......
Page 3: ...C200H MC221 Motion Control Unit Operation Manual Details Revised June 2010 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 10: ......
Page 12: ......
Page 16: ...xvi ...
Page 42: ......
Page 48: ......
Page 196: ......
Page 212: ......
Page 242: ......
Page 258: ......
Page 304: ......