![background image](http://html1.mh-extra.com/html/omron/c200h-mc221/c200h-mc221_operation-manual_742324067.webp)
47
Servo Parameters
When the servo parameter is changed, the changed value will become valid in
real time.
Axis
Address
R/W
Name
Description
X
4600
R/W
Accumulated pulses
warning value
Sets the accumulated pulses warning value within a
range of 0 to 65,000 pulses.
0
0
0 x10
4
x10
3
x10
2
x10
1
x10
0
L+1
L
4601
R/W
In-position
Sets to check the in-position within a range of 0 to
999 pulses.
0
0
0
0
0 x10
2
x10
1
x10
0
L+1
L
4602
R/W
Position loop gain
Sets the position loop gain within a range of 5/s to
250/s.
0
0
0
0
0 x10
2
x10
1
x10
0
L+1
L
4603
R/W
Position loop FF gain
Sets the position loop FF gain within a range of 0% to
100%.
0
0
0
0
0 x10
2
x10
1
x10
0
L+1
L
4604
R/W
Backlash compensation
value
Sets the backlash compensation value within a range
of 0 to 999 pulses.
0
0
0
0
0 x10
2
x10
1
x10
0
L+1
L
Y
4625
R/W
Accumulated pulses
warning value
Refer to the corresponding X-axis parameters.
4626
R/W
In-position
4627
R/W
Position loop gain
4628
R/W
Position loop FF gain
4629
R/W
Backlash compensation
value
Details of Data Transmission and Reception Units
Section 4-4
Summary of Contents for C200H-MC221 -
Page 1: ...Cat No W315 E1 03 Motion Control Unit C200H MC221 OPERATION MANUAL ...
Page 2: ......
Page 3: ...C200H MC221 Motion Control Unit Operation Manual Details Revised June 2010 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 10: ......
Page 12: ......
Page 16: ...xvi ...
Page 42: ......
Page 48: ......
Page 196: ......
Page 212: ......
Page 242: ......
Page 258: ......
Page 304: ......