10
Connection Example
The following diagram shows an example connection for just the X axis. Connect
Y-axis wires in the same way.
Terminal
no.
Label
+24 V
0 V
Normally closed
Normally open
Emergency
stop input
CCW limit
input
Origin
proximity
input
CW limit
input
Common
Common
Common
Common
Common
Common
DC
power
supply
Note
OUT1 or OUT2 of the Terminals is not available for the C200H-MC221.