Nortel Proprietary
8..19..20..21..22..23..24..25..26..27..28..29..30..31..32..33..
34..35..36..37..38..39..40..41..42..43..44..file read complete
Program filename = /C:/exec
Checksum = 0xdef4797d
length = 0x59d1fc
Verifying checksum ...
Upgrade completed OK
Reboot the pack to run new loadware
Where “C:/newexec” is the location of the file copied onto the compact flash
card.
7. When the upgrade is complete, remove the original loadware file that was
transferred onto the card. From the shell type:
rm “/C:/newexec” <CR>
Where “C:/newexec” is the location of the file copied onto the compact flash
card.
8. Re-enable the card from overlay 32 on the switch software.
9. Reboot the card.
10. When the card has rebooted completely, at the shell, type:
swVersionShow <CR>
This will return the version of the software currently running on the card eg:
softwareRev: NRAO Rel: 0.83
Planning, Installation and Administration Guide
122
The checksum will vary between
software loads. The release notes
for the upgrade load being applied
should be consulted to identify the
correct value.