2 Mounting and installation
BU 0200 en-US-4920
79
Pos : 175. 16 / Anl eit ungen/ Elektronik/FU und St arter/ 2. Mont age und I nst allati on/AT EX und EAC EX (SK 1xx E, SK 200E)/ SK AT X-POT [ SK 1x0E / SK 2xx E] @ 4\m od_1395840390747_14638. docx @ 123212 @ 5 @ 1
SK ATX-POT
The category 3D variable frequency drive can be equipped with an ATEX-compliant 10
kΩ
potentiometer (SK ATX-POT) which can be used for setpoint (e.g. speed) adjustment on the device.
The potentiometer is used with an M20-M25 extension in one of the M25 cable screw connections.
The selected setpoint can be adjusted with a screwdriver. Due to the detachable cap, this component
complies with ATEX requirements. Permanent operation may only be carried out with the cap closed.
1
Setpoint adjustment using a screwdriver
SK ATX-POT
wire color
Designation
Terminal
SK CU4-24V…
Terminal
SK CU4-IOE
Terminal
SK 2x0E
Red
+10 V reference
[11]
[11]
[11]
Black
AGND/0 V
[12]
[12]
[12]/[40]
Green
Analog input
[14]
[14]/[16]
[14]/[16]
Pos : 175. 17 / Anl eit ungen/ Elektronik/FU und St arter/ 2. Mont age und I nst allati on/AT EX und EAC EX (SK 1xx E, SK 200E)/ INFORM ATI ON (EX) - Bremswi derst ände [SK 1x 0E, SK 2xx E] @ 1\m od_1342605607279_14638. docx @ 34179 @ @ 1
Information
Internal braking resistor "SK BRI4-…"
If an internal braking resistor of type SK BRI4-x-xxx-xxx is used, activate the power limitation for this under all
circumstances (
Section 2.3.1 "Internal braking resistor SK BRI4-…"). Only the resistors assigned to the
relevant inverter type may be used.
Pos : 175. 18 / Allgemei n/ Allgemei ngültige M odul e/---------Seitenum bruch kom pakt --------- @ 13\m od_1476369695906_0.docx @ 2265496 @ @ 1