2 Mounting and installation
BU 0200 en-US-4920
73
Pos : 167 /Anleit ungen/El ektr onik /FU und St art er/2. M ontage und I nst allation/ Elek trischer Ans chl uss/ SK 1xxE, SK 2xx E, SK 5xxP, SK xxx E-FDS/ St euert eil/Netzt eil, SK CU4 24V … - Ansc hlus sbeispi el_01 [ SK 2xxE] @ 4\mod_1395151789027_14638. docx @ 122317 @ 3 @ 1
2.4.4 Power supply unit SK xU4-24V-… - connection example
Variable Frequency Drives
SK 205E-.../SK 215E-...
C
ont
ro
l t
er
m
in
al
bl
oc
k
44
.
40
.
21
22
23
24
.
.
.
L1 - L2/N - L3
115/230/400V
24V power supply unit
SK TU4-24V-...
(+ SK TI4-TU-NET)
*
or
SK CU4-24V-...
L1 - L2/N
115/230/400V
24V=
GND
10V=
AGND
0-10V
R
L
0-100%
1/3~ 115/230/400V + PE
Control terminal block
44* 40 44* ... 11 14 12 B1
Switch
Potentiometer
10kOhm
Control terminal block
44* 40 44* ... 11 14 12 B1
Control terminal block
44* 40 44* ... 11 14 12 B1
Analog setpoint: 0(2) - 10V
Analog setpoint 0 (4) -
=
* in SK
TU4
-24V-… : Terminal designation
43
instead of 44
AGND
500
Ω
0(4)-20mA
AGND
0(2)-10V
Figure 17: Connection example, power supply unit SK xU4-24V-…
Setting (S1):
(DIP switches)
DIP3 = off, DIP4 = on, DIP5 = off (chapter 4.3.2.2)
(can only be used for 0–10 V or 0–20 mA signals!)
or
recommended
parameter setting,
S1: DIP1-8 = off
P400 [07] = 1
P420 [02] =
2
P420 [01] = 1
P420 [03] =
26 (with 0-10 V/0-20 mA signals)
27 (with 2-10 V/4-20 mA signals)