6 Operating status messages
BU 0200 en-US-4920
229
12.4
Current limit
Limit from potentiometer or setpoint source has switched off.
P400 = 14
12.5
Load monitor
Switch-off due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).
•
Adjust load
•
Change limit values ((P525) ... (P527))
•
Increase delay time (P528)
•
Change monitoring mode (P529)
12.8
AI minimum,
“Analog In minimum”
Switch-off due to undershooting of the 0% adjustment value
(P402) with setting (P401) "0-10 V with switch-off on error 1"
or "....2"
12.9
AI maximum,
“Analog In maximum”
Switch-off due to overshooting of the 100% adjustment
value (P402) with setting (P401) "0-10 V with switch-off on
error 1" or "....2"
Pos : 674 /Allgem ein/ Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0. doc x @ 2265496 @ @ 1
Pos : 675 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/F ehl er E013 [ SK 200E ... SK 5xxE] @ 2\mod_1347454271218_14638. doc x @ 46752 @ @ 1
E013
13.0
Encoder error
No signal from encoder
•
Check 5 V sensor if available
•
Check supply voltage of encoder
13.1
Speed slip error
"Speed slip error"
The slip speed error limit was reached.
• Increase value in P327
13.2
Disconnect. control,
“Shut-down monitoring”
The slip error monitoring was triggered; the motor could not
follow the setpoint.
•
Check motor data P201-P209! (important for current
controllers)
•
Check motor circuit
•
Check encoder settings P300 and following in servo
mode
•
Increase value for torque limit in P112
•
Increase value for current limit in P536
•
Check deceleration time P103 and extend if
necessary
13.5
Reserved
Error message for POSICON
see supplementary manual
13.6
Reserved
Error message for POSICON
see supplementary manual
Pos : 676 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/F ehl er E014 "res erviert" [ SK 200E ... SK 5xxE/SK 500P] @ 2\m od_1347454273854_14638. docx @ 46777 @ @ 1
E014
---
Reserved
Error message for POSICON
see supplementary manual
Pos : 677 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/F ehl er E015 [ SK 180E ... SK 5xxE] @ 2\mod_1347454278051_14638. doc x @ 46802 @ @ 1
E015
---
Reserved
Pos : 678 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/F ehl er E016 [ SK 135E ... SK 5xxE, SK xxx E-FDS] @ 2\m od_1347454280625_14638.docx @ 46827 @ @ 1
E016
16.0
Motor phase error
A motor phase is not connected.
•
Check P539
•
Check motor connection
16.1
Magn. Current Watch
"Magnetizing current
monitoring"
Required exciting current not achieved at moment of switch-
on.
•
Check P539
•
Check motor connection
Pos : 679 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/F ehl er E018 "res erviert" [ SK 2xx E/ SK 5xxE/SK 2xx E-FDS, SK 500P] @ 44\m od_1594726433780_14638.docx @ 2645278 @ @ 1
E018
18.0
Reserved
Error message for “Safe Pulse Block”, see supplementary
instructions
Pos : 680 /Anleit ungen/El ektr onik /FU und St art er/6. M eldung en zum Betriebsz ust and/Störm eldung en (Auflist ung)/F ehl er E019 [ SK 180E/ SK 2x xE/SK 5xxE/SK2xxE-FD S, auß er SK 500P] @ 2\mod_1347454285788_14638. docx @ 46877 @ @ 1
E019
19.0
parameter ident.
"Parameter identification"
Automatic identification of the connected motor was
unsuccessful