NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
212
BU 0200 en-US-4920
SK 2xxE
[-08] =
Ext. Al 1 2. IOE,
"External analog input 1 2nd IOE"
,
AIN1 of the second I/O extension
(SK xU4-IOE) (= analog input 3)
[-09] =
Ext. Al
2 2. IOE,
"External analog input 2 2nd IOE"
,
AIN2 of the second I/O extension
(SK xU4-IOE) (= analog input 4)
Pos : 581 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P710 – Spannung Analog ausg ang [SK 1x0E, SK 2xx E, SK 2x xE-FD S] @ 2\m od_1346932205766_14638. docx @ 43532 @ @ 1
P710
[-01]
[-02]
Analog output volta.
(analog output voltage)
0.0 ... 10.0 V
Displays the delivered value of analog output.
[-01] =
IOE-1,
AOUT of the first I/O extension (SK xU4-IOE)
[-02] =
IOE-2,
AOUT of the second I/O extension (SK xU4-IOE)
Pos : 582 /Allgem ein/ Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0. doc x @ 2265496 @ @ 1
Pos : 583 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P711 – Zust and Digital e Ausgäng e [ SK 2xxE, SK 2xx E-FDS] @ 2\mod_1346932206390_14638. doc x @ 43556 @ @ 1
P711
State of relays
(state of digital outputs)
00000 ... 11111
(bin)
or
00 ... FF
(hex)
Indicates the actual status of the digital outputs of the variable frequency drive.
Bit 0 =
Digital output 1
Bit 1 =
Mechanical brake
Bit 2 =
Digital output 2
Bit 3 =
reserved
Bit 4 =
Digital output 1, IO extension 1
Bit 5 =
Digital output 2, IO extension 1
Bit 6 =
Digital output 1, IO extension 2
Bit 7 =
Digital output 2, IO extension 2
Pos : 584 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P711 – Zust and Digital e Ausgäng e_T eil2/2 [ SK 1x 0E, SK 2x xE, SK 2xx E-FDS] @ 9\m od_1448448278913_14638.docx @ 266831 @ @ 1
Bits 7-4
Bits 3-0
Minimum value
0000
0
0000
0
Binary
hex
Maximum value
1111
F
1111
F
Binary
hex
Simple Box:
The binary bits are converted to a hexadecimal value and displayed.
Parameter Box:
The bits are displayed increasing from right to left (binary).
Pos : 585 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P714 – Betriebs dauer @ 0\mod_1328172684685_14638.docx @ 15118 @ @ 1
P714
Operating time
(operating time )
0.10 ... ___ h
This parameter shows the time for which the VFD was connected to the line voltage and was
ready for operation.
Pos : 586 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P715 – Freigabedauer @ 0\m od_1328172731474_14638. docx @ 15119 @ @ 1
P715
Running time
(enable period)
0.00 ... ___ h
This parameter shows the time for which the VFD was enabled and supplied current to the output.
Pos : 587 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P716 – Ak tuelle Frequenz @ 0\mod_1328172775215_14638. docx @ 15120 @ @ 1
P716
Current frequency
(present frequency)
-400.0 ... 400.0 Hz
Displays the present output frequency.
Pos : 588 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P717 – Ak tuelle Drehz ahl @ 0\m od_1328172889966_14638. docx @ 15121 @ @ 1
P717
Current speed
(present speed)
-9999 ... 9999 rpm
Displays the present motor speed calculated by the VFD.
Pos : 589 /Anleit ungen/El ektr onik /FU und St art er/5. Par ameter/ Par ameter auflist ung (P000 .. .)/P700- P799/Param et er P718 – Ak tuelle Sollfreq uenz @ 0\m od_1328172931732_14638. docx @ 15122 @ @ 1