7 Technical Data
BU 0200 en-US-4920
245
Device model
SK 2xxE…
-112-340-
-152-340-
-182-340-
-222-340-
Size
4
4
4
4
Rated motor power
(4-pole standard motor)
400 V
11.0 kW
15.0 kW
18.5 kW
22.0 kW
480 V
15 hp
20 hp
25 hp
30 hp
Line voltage
400 = 0 – 10 V
3 AC
380 V … 500 V, -20%/+10%, 47 Hz … 63 Hz
Input current
rms
1)
23.6 A
32.0 A
40.5 A
46.5 A
FLA
2)
20.5 A
28.0 A
35.5 A
42.5 A
Output voltage
400 = 0 – 10 V
3 AC
0 … line voltage
Output current
3), 4)
rms
1)
23.0 A
32.0 A
40.0 A
46.0 A
FLA
motor mounting
2)
20.0 A
28.0 A
35.0 A
42.0 A
FLA
wall mounting
2)
20.0 A
28.0 A
35.0 A
42.0 A
Min. braking resistance
Accessories
47
Ω
33
Ω
27
Ω
24
Ω
Motor mounting (fan cooling 5), integrated in device)
4)
Max. continuous power/max. continuous current
S1-40°C 11.0kW/23.0A
15.0kW/32.0A
18.5kW/40.0A
22.0kW/46.0A
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
40°C
50°C
50°C
40°C
49°C
49°C
40°C
41°C
41°C
40°C
41°C
41°C
Wall mounting (fan cooling 5), integrated in device)
4)
Max. continuous power/max. continuous current
S1-40°C 11.0kW/23.0A
15.0kW/32.0A
18.5kW/40.0A
22.0kW/46.0A
Max. permissible ambient temp. with rated output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
45°C
50°C
50°C
45°C
50°C
50°C
41°C
43°C
43°C
40°C
42°C
41°C
General fuses (AC) (recommended)
slow-blowing
35 A
50 A
50 A
63 A
Isc
6)
[A]
UL-approved fuses (AC)
Class
10 00
0
65 00
0
100 0
00
F
u
s
e
CC, J, R, T, G, L (600 V)
x
60 A
60 A
60 A
60 A
CB
7)
(600 V )
x
60 A
60 A
60 A
60 A
1) Pay attention to derating curve (
section 8.4.4 "Reduced output current due to line voltage").
2) FLA –
Full Load Current
, maximum current for the entire line voltage range as stated above (380 V – 500 V) according to UL/CSA
3) FLA (S1-40°C)
4) SK 21xE and SK 23xE devices: For use of safe functions (functional safety: STO and SS1) the restrictions regarding the permissible temperature
range according to
must be noted.
5) Fan cooling, temperature-controlled: ON= 55°C, OFF= 50°C,
After-run time when 50°C limit undershot and enable removed: 2 minutes
6) Maximum permissible short-circuit current in the grid
7) "inverse time trip type" in acc. with UL 489