4.3.4 Commissioning examples
All SK 2xxE devices can basically be operated in the condition in which they are delivered. Standard
motor data of a standard NORD 4-pole asynchronous motor of the same power is parameterized. The
PTC input must be bypassed if no motor PTC is available. Parameter (P428) must be changed if an
automatic startup with "Power On" is required.
Pos : 252 /Anleit ungen/El ektr onik /FU und St art er/4. I nbetriebnahm e/ SK 1x xE, SK 2xx E, -FD S/I nbetriebnahme G erät /Minimalk onfigur ation SK 2x0E [ SK 2xxE} @ 1\m od_1343222569379_14638. docx @ 37598 @ 4 @ 1
4.3.4.1
SK 2x0E minimum configuration
The variable frequency drive provides all the necessary control voltages (24 VDC/10 VDC).
Variable Frequency
Drives
SK 2x0E-...
C
ont
ro
l t
er
m
in
al
bl
oc
k
12*
14**
11
.
43
.
21
22
.
38
39
L1 - L2/N - L3
230/400V
1/3~ 230/400V + PE
Switch S1
Potentiometer
10kOhm
* in SK 220E and SK230E: use GND (terminal 40)
** in SK 220E and SK230E: use Analog In 2 (Terminal 16) and parameterise P400[02] to {1}
Motor PTC
thermistor
Function
Setting
Setpoint
External 10
kΩ potentiometer
Controller enable
External switch S1