NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
244
BU 0200 en-US-4920
Device model
SK 2xxE…
-301-340-
-401-340-
-551-340-
-751-340-
Size
2
2
3
3
Rated motor power
(4-pole standard motor)
400 V
3.0 kW
4.0 kW
5.5 kW
7.5 kW
480 V
4 hp
5 hp
7 ½ hp
10 hp
Line voltage
400 V
3 AC
380 … 500 V, -20%/+10%, 47 Hz … 63 Hz
Input current
rms
1)
7.0 A
8.9 A
11.7 A
15.0 A
FLA
2)
6.3 A
8.0 A
10.3 A
13.1 A
Output voltage
400 = 0 – 10 V
3 AC
0 … line voltage
Output current
3), 4)
rms
1)
7.5 A
9.5 A
12.5 A
16.0 A
FLA
motor mounting
2)
6.7 A
8.5 A
11.0 A
14.0 A
FLA
wall mounting
2)
5.5
a)
A
(S1-40°C)
5.5 A
b)
(S1-40°C)
8.0 A
c)
(S1-40°C)
8.0 A
d)
(S1-40°C)
Min. brake resistance
Accessories
110
Ω
110
Ω
68
Ω
68
Ω
Motor mounting (ventilated), or wall mounting with SK TIE4-WMK-L-1 (or -2) (ventilated)
4)
Max. continuous power/max. continuous current:
S1-50°C
S1-40°C
2.2kW/5.5A
3.0kW/7.5A
3.0kW/8.0A
4.0kW/9.5A
4.0kW/11.8A
5.5kW/12.5A
5.5kW/13.8A
7.5kW/16.0A
Max. permissible ambient temp. with rated output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
43°C
45°C
45°C
41°C
45°C
41°C
48°C
50°C
50°C
43°C
45°C
45°C
Wall mounting (unventilated)
4)
Max. continuous power/max. continuous current:
S1-50°C
S1-40°C
S1-30°C
1.1kW/3.1A
1.5kW/4.0A
1.5kW/4.8A
1.5kW/4.0A
1.5kW/4.9A
2.2kW/5.7A
1.5kW/5.3A
2.2kW/6.9A
3.0kW/8.4A
2.2kW/6.3A
3.0kW/7.9A
4.0kW/9.4A
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
-3°C
0°C
0°C
-20°C
-5°C
-15°C
1°C
15°C
5°C
-18°C
-5°C
-10°C
General fuses (AC) (recommended)
slow-blowing
16 A
16 A
20 A
25 A
Isc
5)
[A]
UL-approved fuses (AC)
Class
10 00
0
65 00
0
100 0
00
F
us
e
6)
RK5
(x)
x
10 A
30 A
30 A
30 A
CC, J, R, T, G, L
(x)
x
10 A
30 A
30 A
30 A
Bussmann
FRS-
(x)
x
R-10
R-30
R-30
R-30
CB
7)
(≥
230 / 400 V)
x
10 A
25 A
25 A
25 A
1) Pay attention to derating curve (
section 8.4.4 "Reduced output current due to line voltage").
2) FLA –
Full-load current
, maximum current for the entire line voltage range as stated above (380 V – 500 V) according to UL/CSA
3) FLA (S1-45°C), FLA motor mounting: relates to a motor with fans
4) SK 21xE and SK 23xE devices: For use of safe functions (functional safety: STO and SS1) the restrictions regarding the permissible temperature
range according to
must be noted.
5) Maximum permissible short-circuit current in the grid
6) The use of an SK TU4-MSW(-…) module, limits the permissible short circuit in the grid to 10 kA
7) "inverse time trip type" in acc. with UL 489
a) 6.7 A when using a suitable fan
a) 8.5 A when using a suitable fan
a) 11.0 A when using a suitable fan
a) 14.0 A when using a suitable fan