103
ADVANCED PARAMETER-SETTING MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
09.92
: Logic function 6 source 3
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 3 for logic function 6.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.93
: Logic function 6 source 3 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 3 of logic function 6.
Disabled (0):
Source 3 not inverted.
Enabled (1):
Source 3 inverted.
09.94
: Logic function 6 source 1
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 1 for logic function 6.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.95
: Logic function 6 source 1 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 1 of logic function 6.
Disabled (0):
Source 1 not inverted.
Enabled (1):
Source 1 inverted.
09.96
: Logic function 6 source 2
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 2 for logic function 6.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.97
: Logic function 6 source 2 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 2 of logic function 6.
Disabled (0):
Source 2 not inverted.
Enabled (1):
Source 2 inverted.
09.98
: Logic function 6 output invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert the output of logic function 6.
Summary of Contents for LEROY-SOMER Powerdrive FX
Page 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Page 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 175: ...175 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...