98
ADVANCED PARAMETER-SETTING MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
5.10.2 - Explanation of parameters in menu 9
09.01
: Logic function 1 output
09.02
: Logic function 2 output
Adjustment range : Disabled (0) or Enabled (1)
Format: 8 bits
Indicate the state of the output of logic functions 1 and 2.
09.03
: Motorised potentiometer reference
Adjustment range : ± 100.0%
Format: 16 bits
Indicates the motorised potentiometer reference level.
09.04
: Logic function 1 source 1
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 1 for logic function 1.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.05
: Logic function 1 source 1 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 1 of logic function 1.
Disabled (0):
Source 1 not inverted.
Enabled (1):
Source 1 inverted.
09.06
: Logic function 1 source 2
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 2 for logic function 1.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.07
: Logic function 1 source 2 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert source 2 of logic function 1.
Disabled (0):
Source 2 not inverted.
Enabled (1):
Source 2 inverted.
09.08
: Logic function 1 output invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : Disabled (0)
Format: 8 bits
This parameter is used to invert the output of logic function 1.
Disabled (0):
Output not inverted.
Enabled (1):
Output inverted.
09.09
: Not used
09.10
: Logic function 1 output destination
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter defines the internal parameter which will be
assigned by the output of logic function 1.
Only non-protected «bit» type parameters can be addressed.
If an unsuitable parameter is programmed, the destination will
not be taken into account.
09.11
to
09.13
: Not used
09.14
: Logic function 2 source 1
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format : 16 bits
This parameter is used to select source 1 for logic function 2.
Only «bit» type parameters can be used on this input.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
09.15
: Logic function 2 source 1 invert
Adjustment range : Disabled (0) or Enabled (1)
Factory setting : No (0)
Format: 8 bits
This parameter is used to invert source 1 of logic function 2.
Disabled (0):
Source 1 not inverted.
Enabled (1):
Source 1 inverted.
09.16
: Logic function 2 source 2
Adjustment range :
00.00
to
21.51
Factory setting :
00.00
Format: 16 bits
This parameter is used to select source 2 for logic function 2.
Only «bit» type parameters can be used on these inputs.
If an unsuitable parameter is addressed, the input will be frozen
at 0.
Summary of Contents for LEROY-SOMER Powerdrive FX
Page 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Page 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 175: ...175 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...