18
QUICK SETUP MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
Parameter Address
Name
Adjustment range
Factory setting
Ctr.11
10.80
Auto reset type
Controlled
Automatic
Auto for 1081, 1082, 1083, 1084
Auto except 1081, 1082, 1083, 1084
Controlled
Ctr.12
05.59
Rotation direction
Clockwise
C/clockwise
Clockwise
Ctr.13
05.14
Open loop mode selection
Rs measured each run
Rs not measured
Linear U/F law with boost
Rs measured after each factory setting
Rs measured after each power up
Square U/F law with boost
Rs measured
after each
power up
Ctr.14
05.12
Autotune
None
Stationary: motor data completed
Rotating: motor data incompleted
Encoder offset measure/rotor parking
Encoder offset measure/signal injection
None
• Mtr MENU: MOTOR NAMEPLATE
Parameter Address
Name
Adjustment range
Factory setting
Mtr.01
05.06
Motor rated frequency
0.01 to 590.00 Hz
50.00 Hz
Mtr.02
05.07
Motor rated current
0.00 to 2.2 x
11.32
Depends
on rating
Mtr.03
05.08
Motor rated speed
0.00 to 60000.00 rpm
1500.00 rpm
Mtr.04
05.09
Motor rated voltage
0 to 999 V
400 V
Mtr.05
05.10
Rated power factor
0.00 to 1.00
0.85
Mtr.06
05.70
PTC validation
Disabled
Drive terminal
Encoder option terminal
2 PTC inputs
Disabled
Mtr.07
05.50
Motor ventilation
Not cooled
Self cooled
Forced cooling
Self cooled
If Ctr.02 = PM motor (Servo) in vector control mode:
Mtr.08
05.24
Transient inductance / Ld
0.000 to 9000.000 mH
0.000 mH
Mtr.09
05.33
Motor volt per 1000 rpm (Ke)
0 to 32000 V
98 V
If MDX-ENCODER option detected:
Mtr.10
03.38
Encoder type
Incremental
Reserved
U, V, W only
Incremental UVW
Hall effect sensor
Software 1/Voltage oriented
Software 2/Voltage oriented
Software 3/ adaptative model
Software 4/flux oriented
Software 5
Resolver
Software
encoder n° 2
Mtr.11
03.34
Encoder lines per revolution
0 to 32000 lpr
1024 lpr
Mtr.12
03.36
Encoder supply voltage
5V or 15V
5V
Mtr.13
03.25
Position feedback phase angle
0.0 to 359.9°
0.0°
Summary of Contents for LEROY-SOMER Powerdrive FX
Page 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Page 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 175: ...175 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...