• The drives use an algorithm which is adjusted by
parameters. The performance levels obtained de-
pend on the parameter setting. Inappropriate set-
tings may have serious consequences for personnel and
machinery.
• The drive parameters must only be set by appro-
priately qualified and experienced personnel.
• Before powering up the drive, check that the power
connections (mains supply and motor) are correct, and
that any moving parts are mechanically protected.
• Before setting the drive parameters, all instruc-
tions relating to installation and connection contained in
the installation document or the manual supplied with the
drive must have been strictly observed.
• Users of the drive should take particular care to
avoid starting it accidentally.
2 - PARAMETER-SETTING
INTERFACE
2.1 - Presentation
The interface consists of a touch screen which can be used to
access various menus. It is supplied with its own connection
cable.
Do not connect/disconnect the interface when the
drive is powered up.
After a loading phase following powering-up of the drive, the
parameter-setting interface displays the following screen:
Ref.
Function
A
Touch screen
B
Touch button allowing simple access to the main
menu
C
«COM» LED indicating the state of communication
with the drive
Off: no communication
Flashing: communicating
D
«CPU» LED indicating the state of the interface CPU
E
«PWR» LED indicating the state of the interface
power supply
F
Touch-sensitive buttons for language selection
(can take a few minutes to load)
The interface operating temperature is -10°C to +50°C.
After 10 minutes without activity on the display, it returns to the
«
Reading mode
» screen.
2.2 - Interface architecture
From the welcome screen, press the touch-sensitive key
B
as
indicated below to access the main page of the parameter-
setting interface, consisting of 5 touch-sensitive buttons:
- Informations:
Can be used to obtain Informations very
quickly about the drive, the fieldbus option, the parameter-
setting interface, and also provides access to the language
selection.
- Reading mode:
Is used to display the status of the drive
when stopped or during operation, as well as its main
measurement points.
- Setting:
Used for reading and/or modification of all the drive
parameters, saving parameters, as well as to set the date
and time on the display.
- Keypad control:
Gives direct access to motor control via
the touch screen (Run/Stop, direction of rotation, speed
reference). These screen parameters can be set using the
Setting/ Keypad Control setup via the keypad menu. keypad
control is disabled in factory-set configuration.
- Trip history:
Gives a quick overview of the last 10 drive
trips.
-
: This button is accessible on all screens in factory-set
configuration and is used to give a stop command or
reset a trip. To disable it, see section 2.2.3.4.
At any time and regardless of the screen displayed, the
button can be used to return to previous pages, as far as
the interface main page.
C
A
B
F
D
E
Summary of Contents for LEROY-SOMER Powerdrive FX
Page 1: ...4647 en 2017 09 e Powerdrive MD2 FX Commissioning manual R f rence...
Page 41: ...41 QUICK SETUP MODE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 174: ...174 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...
Page 175: ...175 MAINTENANCE Commissioning manual Powerdrive MD2 FX 4617 en 2017 09 e Notes...