45
ADVANCED PARAMETER-SETTING MODE
Commissioning manual Powerdrive MD2/FX
4617 en - 2017.09 / e
• Limiting and filters
Menu 2
Pre-skip
filter
reference
Pre-ramp
reference
1
2
Reference in
skip zone
1
1
0
0
0
1
X(-1)
Menu 20
1
0
1
OR
Skips
Speed
Reference
band
0
MENU 8
MENU 6
Jog select
indicator
Bipolar
reference
enable
Jog
reference
Reverse
select indicator
Reference
enable indicator
A
DI1/PTC
DI2
DI3
DI4
DI5
Maximum
reference
clamp
Minimum
reference
clamp
01.02
01.03
01.35
01.13
01.12
01.11
01.05
01.29
01.30
01.31
01.32
01.10
01.07
01.06
01.06
01.06
01.07
01.06
01.06
B
B’