Security
Description
This system supports the following built-in simple security features.
•
Warning Message (Watch mode)
Automatically and periodically sends the Watching (VRS) Message from the built-In Speaker on the
Multiline Terminal or external paging adapter during night mode.
Accommodates 3rd Party PIR (Passive Infrared Sensor) or Emergency Button to provide additional
security features such as Auto-Emergency Call with Warning (VRS) Message sending.
•
Room Monitoring from Outside
Access Multiline Terminal from outside to monitor the room sound.
•
Remote Inspection
Automatically ring the terminal with pre-programmed schedule in order to check whether users
answer or not. If not answered, Emergency Call is placed to predefined destination automatically.
Conditions
Warning Message (Watch Mode)
• Watch mode can provide “Watching message” in a preprogrammed interval via internal paging
group terminals and/or external paging group during defined schedule such as night time.
• Watch mode starts and stops automatically according to PRG 20-47-01 setting.
• Watch mode can start and stop manually using Service code (PRG 11-12-63) or function key (
*
32
)
assignment.
• To connect security sensor set PRG 20-46-01 Sensor mode to (1; on) and connect to Door Phone
port instead of Door phone.
• Security sensor can be connected to Analog Extension Port 1, 2 of 082U-B1. A maximum of 6
sensors can be connected.
- Applied voltage when sensor is Off: 25V
- Loop current when sensor is On: 40mA
PRG 82-21 needs to set up according to used sensor.
• Security sensor can start and stop automatically according to PRG 20-48-01 setting.
• Security sensor can start and stop manually using Service code (719) or function key (
*
33
assigned
after the timer (PRG 20-55-01) time-outs).
• When the system receives a sensor detection signal from a Security sensor, either items (1 or 2) or
both items (1 and 2) can be programmed.
1.
A repeated “Warning message” is provided via internal paging group terminals and/or external
paging group.
2.
An emergency call can be placed to a pre-programmed destination using a pre-recorded VRS
message.
After finishing the VRS message, the person at the receiving destination can monitor the
situation using Multiline Terminal defined in PRG 20-46-10. Also, by pressing
*
key from
outside it is possible to enable a two-way path.
• If all VRS channels are busy, a tone will be provided instead of VRS message, such as Watch,
Warning or for destination message.
• If a VRS message is not recorded, a tone will be provided.
• A VRS message can be provided to extension Speaker only when the extension is idle. But if Watch
or Warning message happened during normal paging is working, normal paging will stop and send
Watch or Warning message.
• Warning messages have a higher priority than Watch messages when both are received at same
time.
ISSUE 1.0
SL2100
Features and Specifications Manual
1-751
S
Summary of Contents for UNIVERGE SL2100
Page 1: ...Features and Specifications Manual GVT 010794 401 00 AU ISSUE 1 0 May 2017 ...
Page 14: ...MEMO SL2100 ISSUE 1 0 R 4 Regulatory ...
Page 313: ...Operation None ISSUE 1 0 SL2100 Features and Specifications Manual 1 299 D ...
Page 412: ...Operation None SL2100 ISSUE 1 0 1 398 Howler Tone Service H ...
Page 572: ...LCR Dial LCR Dial Editing SL2100 ISSUE 1 0 1 558 LCR Least Cost Routing L ...
Page 573: ...LCR Cost Center Code ISSUE 1 0 SL2100 Features and Specifications Manual 1 559 L ...
Page 846: ...2 Press Hold key and talk with the party SL2100 ISSUE 1 0 1 832 Tone Override T ...
Page 878: ...Operation None SL2100 ISSUE 1 0 1 864 Universal Slots U ...
Page 946: ...MEMO SL2100 ISSUE 1 0 1 932 Warning Tone for Long Conversation W ...
Page 976: ...MEMO SL2100 ISSUE 1 0 3 6 Features Availability by Software Revision ...
Page 977: ...MEMO ISSUE 1 0 SL2100 Features and Specifications Manual 3 7 ...
Page 978: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...