• The hardware/software requirements to run PCPro :
Item
Requirement
CPU
Depending on Microsoft Operation System environment
Memory
Depending on Microsoft Operation System environment
Operating System (OS)
Windows Vista
Windows 7 (32– and 64–bit)
Windows 8 /8.1 (32 - and 64 -bit)
Windows 10 (32 - and 64 -bit)
Other
Microsoft Internet Explorer 7.0 or higher
Communication Port
LAN or Modem
Disk Space
1 GByte for PCPro (minimum)
TCP Port
TCP port 8000 must be open between the terminal and the host PC for
uploading/ downloading via LAN. PCPro/WebPro TCP port is set for
8000 at default, but can be changed via WebPro using PRG 90-38-02.
PRG 90-38-02 is not accessible from Telephone Programming or PCPro.
TCP port 5963 is required to be open if the Debug Terminal is going to be
used.
Screen Resolution
800 x 600 (minimum)
1024 x 760 (recommended)
• The hardware/software requirements to run WebPro :
Item
Requirement
Browser
Microsoft Internet Explorer 11 (or higher)
Google Chrome 52 or higher
Firefox 42 or higher
Microsoft Edge
Network
IP connection to the KTS
Screen Resolution
800 x 600 (minimum)
1024 x 760 (recommended)
• You can have a maximum of four users logged into WebPro same time.
• You can have up to two phones in programming mode same time.
• You can have total of four users in programming mode at same time. This can be a any mix of
Telephone programming user and Webpro user as long as it wont exceed four users.
• Only One user can be logged into PC PRO. While user is logged into PC PRO Webpro, Telephone
programming couldn't be used.
• When programming via WebPro/PCPro, it requires you to logout before the system fully applies the
changes.
• In the System Data configuration window, you can open/close the system data by clicking the
system data you want to open/close.
• Some programs may need the system to reset/reboot order for the system to effect the change that
been made. These Programs are: 80-01, 80-02-01, 80-02-02, 80-02-03, 80-02-04, 80-03, 80-04.
• When using a Board Configuration to update your system. Please disconnect after upload is done.
Then please re-start the system order for system to function properly. Until System re-start phone
will not work.
• PCPro Login account can be set up to 20 accounts.
• PCPro Connection account can be set up to 200 accounts.
• PCPro and WebPro have been enhanced allowing T1/ISDN layer 1 status, System Alarms and
SRAM information to be viewed. The SRAM displays Day/Night Mode information, Trunk information
(Trunk to Trunk Transfer Set/Not Set, Trunk disabled), Read List, Department Group information
(DND, Transfer settings) and Extension information (Forwarding settings, Alarm settings, DND,
BGM and more).
• WebPro supports remote upgrade and is only available in the Manufacture (MF) and Installer (IN)
level logins.
SL2100
ISSUE 1.0
1-700
PC Programming
P
Summary of Contents for UNIVERGE SL2100
Page 1: ...Features and Specifications Manual GVT 010794 401 00 AU ISSUE 1 0 May 2017 ...
Page 14: ...MEMO SL2100 ISSUE 1 0 R 4 Regulatory ...
Page 313: ...Operation None ISSUE 1 0 SL2100 Features and Specifications Manual 1 299 D ...
Page 412: ...Operation None SL2100 ISSUE 1 0 1 398 Howler Tone Service H ...
Page 572: ...LCR Dial LCR Dial Editing SL2100 ISSUE 1 0 1 558 LCR Least Cost Routing L ...
Page 573: ...LCR Cost Center Code ISSUE 1 0 SL2100 Features and Specifications Manual 1 559 L ...
Page 846: ...2 Press Hold key and talk with the party SL2100 ISSUE 1 0 1 832 Tone Override T ...
Page 878: ...Operation None SL2100 ISSUE 1 0 1 864 Universal Slots U ...
Page 946: ...MEMO SL2100 ISSUE 1 0 1 932 Warning Tone for Long Conversation W ...
Page 976: ...MEMO SL2100 ISSUE 1 0 3 6 Features Availability by Software Revision ...
Page 977: ...MEMO ISSUE 1 0 SL2100 Features and Specifications Manual 3 7 ...
Page 978: ...Features and Specifications Manual NEC Corporation ISSUE 1 0 ...